pH متر مدل HQ440 ساخت کمپانی هک آمریکا
Laboratory two channel multi meter for pH, ORP,ISE, Conductivity, TDS, Resistivity, Salinity and LDO. Instrument with electrode holder, without electrodes.
  • Have confidence in your readings!
  • Optimised handling
  • User friendly
  • Fully GLP compliant communication and documentation
  • Reliable O2 results with minimum effort

The digital meter/electrode system HQD combines reliability, flexibility and ease of use. Interchangeable INTELLICAL electrodes are recognised automatically and store all relevant data.

AccuracyORP: 0.1 mV
Auto-buffer recognitionpH: Colour-coded: 4.01, 7.00, 10.01
IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45
DIN: 1.09, 4.65, 9.23
User-defined custom buffer sets

Conductivity: Demal (1D / 0.1D / 0.01D);
Molar (0.1M / 0.01M / 0.001M);
NaCl (0.05%; 25μS/cm; 1000μS/cm; 18mS/cm);
Standard sea water;
User defined
BOD5/CBOD resolutionAvailable when integrated with Hach WIMS BOD Manager software
BacklightIncluded
BenchtopYes
Cable resistance correctionDigital - not needed
Calibration curves displayCalibration summary data logged and displayed
Calibration intervals/alerts/reminder2 hours to 7 days
Casing IP ratingIP54
CommunicationDirect to PC (Bi-directional) via USB virtual serial port
ComplianceCE
Conductivity accuracy± 0.5 % in 1 μS/cm to 200 mS/cm range
Conductivity measurement range0.01 μS/cm to 200 mS/cm
Conductivity resolution5 digits with 2 digits after decimal point
Custom calibration standardsUser-defined standard sets
DO measurement range0.00 to 20.0 mg/L DO
DO resolution0.01 mg/L or 0.1 % DO saturation
Data StorageAutomatically store in "press to read" mode and interval measurement mode. Manually store in "continuous read" mode.
Data loggerDownload via USB connection to PC or flash stick. Automatically transfer entire data log or as readings are taken.
Data storage500 results
Digital (intelligent) electrode inputs2 channel
Dimensions (H x W x D)86 mm x 175 mm x 234 mm
DisplayContinuous measurement or "press to read" mode available with averaging function for LDO measurement.
DisplayBacklit Graphical LCD
Display readings from one or two probes
Simultaneous readings from two probes (HQ440d only)
pH: pH, mV, temperature
Conductivity: Conductivity, TDS, salinity, resistivity, temperature
LDO: dissolved oxygen, pressure, temperature
LBOD: dissolved oxygen, pressure, temperature
ORP/Redox: mV, temperature
ISE: Concentration, mV, temperature
Display type240 x 160 pixel Backlit Graphical LCD
Environmental conditions: relative humidity90 % relative humidity (non-condensing)
Environmental conditions: temperature5 to 45 °C
Fixed buffer selectionIUPAC standards (DIN 19266), Technical buffer (DIN 19267), 4-7-10 series, or user defined
ISE direct measurementYes
ISE electrode calibrationElectrode specific - see electrode user instructions
InputsM12 digital (2) for INTELLICAL electrodes
Internal result storage capacity500 results
Language user interfacesSelectable: English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Swedish, Czech, Russian
Length235 mm
ORP electrode calibrationPredefined ORP standards (including Zobell's solution)
ORP measurement range-1500 to 1500 mV
Operating InterfaceKeypad
Operating error messagesFull text messages
OutputsIntegrated USB type A (USB flash memory device, printer, keyboard); integrated USB type B (PC)
PC Data Transfer SoftwareFree download
Power Requirements (Voltage)7 V
Pressure compensationAutomatic
PrinterAs optional accessory
Resistivity resolutiondigits max.
Resolution0.1
Resolution3 digits max.
Result IDTime stamp, user ID, sample-ID, etc.
Salinity measurement range0 to 42 g/kg
Salinity resolution0.01 ppt
TDS measurement range0.0 to 50.0 mg/L
Temperature accuracy± 0.3 °C
Temperature compensationAutomatic, off, manual (auto correction is parameter dependent) Automatic Temperature compensation for pH
Temperature range-10 to 110 °C
Temperature resolution0.1 °C
Warranty3 years
Water ResisitanceMeter Casing: Spray-resistant and dust resistant (IP54)
Weight0.850 kg without batteries
mV accuracy± 0.1 mV
mV measurement at stable reading5 stabilisation settings
mV measurement range-1500 to 1500 mV
mV resolution0.1 mV
nullNot linear (natural waters DIN 38404 & EN ISO 7888 or NaCL), linear coefficient, no compensation
pH Measurement at stable reading5 stabilisation settings

فروشنده: آزمیران
گارانتی اصالت و سلامت کالا
پشتیبانی ۷ روز هفته ۲۴ ساعته
۰ تومان
محصولات مرتبط

:

الکترود WTW™ SenTix™ 62 pH
۱۶,۶۸۰,۰۴۱تومان
الکترود WTW™ SenTix™ 60 pH
۱۵,۹۸۵,۰۴۱تومان

ابزار وبلاگ